Ti-6Al-4V ELI

Titanium

Ti-6Al-4V ELI

Low-interstitial titanium alloy, implants. (ASTM Gr23; equiv Grade 23 ELI). Nominal values—confirm mill certificate.

Chemical Composition (%)

AL5.5
V3.5
FE0.13
O0.13

Mechanical Properties

Tensile:≥860 MPa;Yield:≥795 MPa;Elong:≥10%

Chinese Standard

ASTM Gr23 Ti-6Al-4V ELI

Equivalent Standards

Grade 23 ELI

Applications

超低间隙6Al-4V,生物植入。,"Bar

Available Forms

Plate"

Uses

Titanium alloy with outstanding strength-to-weight ratio and corrosion resistance, especially in chloride environments. Used in aerospace airframes, jet engines, medical implants, marine and chemical plant.

Heat Treatment

Solution treated 900–980 °C and aged 480–600 °C (α+β grades); anneal 700–800 °C; β-annealed for creep resistance. Keep below β-transus to avoid grain growth.

Precautions

Use sharp, high-rake tooling and appropriate coolants; galling/adhesive wear can occur. Titanium reacts with hydrogen and chlorine — keep out of pickling/HCl environments.